Operation & Installation ManualContinuous Vacuum/PressureConveying SystemsSingle- and Dual-Blower SystemsImportant! Read Carefully Before Attempt
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 91 General Information1-1 Models CoveredAEC single vacuum pressure (SVP) systems have
Page 10 Single- and Dual-Blower Continuous Vacuum/Pressure SystemsSystems Used for Powders or Dusty MaterialsMaterial lines on the vacuum side of the
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 11Figure 2Typical Dual Blower System for Free-Flowing PelletsProduct fromrail carProd
Page 12 Single- and Dual-Blower Continuous Vacuum/Pressure Systems1-5 OptionsSingle-blower vacuum/pressure systems and dual-blower continuous vacuum a
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 132 Safety2-1 Work RulesInstall, operate, and maintain this equipment according to
Page 14 Single- and Dual-Blower Continuous Vacuum/Pressure Systems2-4 Safety ConsiderationsThe terms NOTICE, CAUTION, WARNING, and DANGERhave specific
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 152-5 General ResponsibilityNO MATTER WHO YOU ARE…Safety is important. Owners, opera
Page 16 Single- and Dual-Blower Continuous Vacuum/Pressure SystemsONLY YOU can make safety work for you by constantly thinkingabout what is safe and w
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 17• NEVER stand or sit where you could slip or stumbleinto the conveying system whil
Page 18 Single- and Dual-Blower Continuous Vacuum/Pressure Systemsare correctly connected to earth ground with an electricalconductor that complies wi
Page 2 Single- and Dual-Blower Continuous Vacuum/Pressure SystemsWrite down your unit serial number(s) ________________ ________________ here
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 19Every effort has been made to incorporate these standards into the design of theVac
Page 20 Single- and Dual-Blower Continuous Vacuum/Pressure Systemselectrical lockout tags. These tags are available at most electricalsupply stores.WA
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 213 Shipping Information3-1 Unpacking and InspectionYou should inspect your AEC vacuu
Page 22 Single- and Dual-Blower Continuous Vacuum/Pressure Systems; Hold the damaged goods with the container and packing materials forpossible inspe
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 234 Installation4-1 Work RulesThe installation, operation, and maintenance of this eq
Page 24 Single- and Dual-Blower Continuous Vacuum/Pressure Systems4-3 Installing Mechanical Components4-3-1 Installing Vacuum and Material TubingUse
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 254-3-2 Using Quick-Change Couplers and Flexible Material HoseYou can attach a quick
Page 26 Single- and Dual-Blower Continuous Vacuum/Pressure Systems4-3-3 Sheltering System ComponentsIf the power unit, control unit, rotary valve, fi
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 27WARNING!Shear points are present at theopen inlet and outlet of the rotary airlock.
Page 28 Single- and Dual-Blower Continuous Vacuum/Pressure SystemsFigure 5Rotary Airlock/Cyclone AssemblyProduct fromrail carProductto siloHigh Level
Please note that our address and phone information has changed. Please reference this page for updated contact information. These manuals are obsolet
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 29IMPORTANT! The power unit is sized for the total conveying distance.In some cases,
Page 30 Single- and Dual-Blower Continuous Vacuum/Pressure Systems 4. Connect the inlet tube of the filter chamber to the outlet of the cyclonesepar
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 31SVP SystemsConnect the pump to a minimum of 80 psi (551.6 kPa/5.52 bars) clean, dry
Page 32 Single- and Dual-Blower Continuous Vacuum/Pressure SystemsVacuum Unit MotorIf the control unit is mounted on the vacuum unit, the vacuum unit
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 33Gradually and evenly tighten the packing gland bolts on either side of the rotor un
Page 34 Single- and Dual-Blower Continuous Vacuum/Pressure SystemsFigure 7Typical SVP System Electrical SchematicLegend------- Field wiring Terminal
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 35Figure 8Typical SVP Electrical Subpanel LayoutFuse holder,30 amp fusesDisconnectswi
Page 36 Single- and Dual-Blower Continuous Vacuum/Pressure SystemsFigure 9Typical CVP/CPP System Electrical SchematicSee Note #3(typical)Legend-------
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 37Figure 10Typical CVP/CPP Electrical Subpanel LayoutFuse holder,30 amp fusesDisconne
Page 38 Single- and Dual-Blower Continuous Vacuum/Pressure Systems- Notes -
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 3Table of Contents1 General Information ...
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 395 Startup, Shutdown, and Operation5-1 Equipment CycleSystems with dual blowers have
Page 40 Single- and Dual-Blower Continuous Vacuum/Pressure SystemsCVP/CPP — Dual Blower Vacuum Pressure SystemsWhen the system is started, the pressur
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 41Notes: The drawing on the previous page shows a typical CVP/CPP system for conveyin
Page 42 Single- and Dual-Blower Continuous Vacuum/Pressure SystemsFigure 12Typical SVP Control Panel Layout42079Q91FOF_0ONPOWER switchPURGE switchSTAR
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 43Figure 13Typical CVP/CPP Control Panel Layout41275Q911LT2LT2PB 1PB3PBPOWERPURGESTAR
Page 44 Single- and Dual-Blower Continuous Vacuum/Pressure Systems5-3 Mechanical Indicators and Safety FeaturesSingle-blower vacuum/pressure systems a
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 45The vacuum/pressure system shuts down if the vacuum switch senses vacuumgreater tha
Page 46 Single- and Dual-Blower Continuous Vacuum/Pressure SystemsIMPORTANT! Do not attempt to adjust the relief valveto more than 1 psig (about 7 kPa
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 47Silo Selector SwitchAEC vacuum/pressure pumps are equipped with a silo selector swi
Page 48 Single- and Dual-Blower Continuous Vacuum/Pressure Systems5-6 Shutting Down the SystemIn certain operating conditions, pressing Emergency Stop
Page 4 Single- and Dual-Blower Continuous Vacuum/Pressure SystemsTable of Contents5 Startup, Shutdown, and Operation... 395-1 Equi
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 49and pressure side material lines of material (set duration in the Auto Shutdown Tim
Page 50 Single- and Dual-Blower Continuous Vacuum/Pressure Systems6 Maintenance6-1 Work RulesThe installation, operation, and maintenance of this equi
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 51MotorsNo lubrication is required.Rotary AirlockAfter the first six months of operat
Page 52 Single- and Dual-Blower Continuous Vacuum/Pressure SystemsPeriodic Checks and Inspections; Check the solid state modules on solid state units
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 53Note: The counterbalance should be adjusted so the flapper remains open about 1/2”
Page 54 Single- and Dual-Blower Continuous Vacuum/Pressure Systems• Remove the two self-tapping screws at the left of the unit holding the mufflerbra
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 557 TroubleshootingWhen a problem is based on a pilot light, check the light bulb bef
Page 56 Single- and Dual-Blower Continuous Vacuum/Pressure SystemsProblem Possible cause Corrective actionThe rotary airlock valve is notoperating.Che
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 57(8) Appendix A Unloading RailcarsUnloading Bulk Railcars2” to 3” Unloading KitsAn i
Page 58 Single- and Dual-Blower Continuous Vacuum/Pressure SystemsThe following illustration shows how the essential components of the AEC, Inc. Probe
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 5Safety ConsiderationsAEC single- and dual-blower continuous vacuum/pressure systems
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 59The Style A pilot hole is ½” (13 mm) from the bottom of the casting. The Style B pi
Page 60 Single- and Dual-Blower Continuous Vacuum/Pressure Systems 7. Turn #4 probe 90° clockwise, tighten the thumb screw onthe adapter, and unload
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 61 5. Swing the caps over the outlet nozzle on both sides of the car and lock in pl
Page 62 Single- and Dual-Blower Continuous Vacuum/Pressure SystemsDry Flow Chem Car (GATX)Attach the adapter assembly to the A style nozzle cap.Materi
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 63Conveying System Options 9The following is a list of options, which your Vacuum/Pre
Page 64 Single- and Dual-Blower Continuous Vacuum/Pressure Systems10 Spare Parts10-1 Spare PartsContinuous Vacuum/Pressure Conveying SystemConsult fac
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 65Technical Assistance 1111-1 Contact Information for Technical AssistanceParts Depa
Page 66 Single- and Dual-Blower Continuous Vacuum/Pressure Systems11-2 Returned Material Policy11-2-1 Credit Returns 1. Prior to the return of any
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 6711-3 WarrantyAEC, Inc. warrants all equipment manufactured by it to be free from d
Page 68 Single- and Dual-Blower Continuous Vacuum/Pressure Systems-Notes-
Page 6 Single- and Dual-Blower Continuous Vacuum/Pressure SystemsAECContinuous Vacuum/PressureConveying SystemsThis conveying system is manufactured b
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 69Safety Tag Information 1212-1 Continuous Vacuum/Pressure System SafetyTagsShear Po
Page 70 Single- and Dual-Blower Continuous Vacuum/Pressure Systems12-2 Continuous Vacuum/Pressure SystemIdentification (Serial Number) Tag(Located o
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 71Service Notes
Page 72 Single- and Dual-Blower Continuous Vacuum/Pressure SystemsService Notes
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 73Service Notes
Page 74 Single- and Dual-Blower Continuous Vacuum/Pressure SystemsService Notes
WarrantyAEC, Inc. warrants all equipment manufactured by it to be free from defects in workmanship andmaterial when used under recommended conditions.
801 AEC Drive • Wood Dale, IL 60191-1198 USA(630) 595-1060 • Fax (630) 595-6641http://www.aecinternet.com
Single- and Dual-Blower Continuous Vacuum/Pressure Systems Page 7Annex B InformationThe following design information is provided for your reference:1
Page 8 Single- and Dual-Blower Continuous Vacuum/Pressure Systems Charts and Figures1Typical Single Blower System for Free-Flowing Pellets 102Typical